Published data. Verified claims. No guessing.

Ask the last guy where his number came from.

Every number, project story and voice-agent answer moves through the same registry: publish, qualify, verify or block.

Motion study derived from a licensed 2017 photograph. Cameron Henderson / Wikimedia Commons / CC BY-SA 4.0

Aerial view of Incheon Grand Bridge

Bridge archive / verification in progress

Incheon Grand Bridge

A legacy formula-owner file identifies this project. Current independent searching confirms the bridge itself, but not yet the product application or the inherited maintenance-performance story.

Bridge identity
Confirmed
Archive association
Internal source
Product application
Recorded in the formula owner’s files
Performance history
Not derived from the bridge — measured on your roof
Photograph: Cameron Henderson / Wikimedia Commons / CC BY-SA 4.0

What we do publish

The numbers we will stand behind.

These are the values the producer publishes and the only performance figures this site states as fact. Everything downstream of them, including any temperature or energy story, stays in the ledger until a measured record exists.

Published radiative split

0.88Reflected away
0.12Absorbed residual
0.89Emittance, releases the residual

Producer-published values. Match the stocked formula and batch before quoting a roof.

The less flattering number

Day one is half the record.

Publishing the aged value alongside the initial value is the whole posture of this page. The second number is less flattering and more useful, and leaving it out would make the first one misleading.

Aged performance

0.88
Initial
0.74
Year 3, published

Reflectance falls as a roof weathers. A brand that only publishes day-one numbers is showing you the easy half of the record.

One public language system

Usable. Review. Blocked.

The claim ledger: usable claims are the published radiative properties; under review are fire test language and the archive project association; blocked are guaranteed temperatures or savings and R-value or fireproof claims.
usable

Published radiative properties

0.88 initial solar reflectance, 0.89 thermal emittance and 0.74 three-year aged reflectance appear in the producer-published table. Match the stocked formula and batch before quoting.

review

Class A and fire-test language

Legacy files reference several tests and ratings. The exact report, product, substrate, assembly and current listing scope have not yet been assembled into a publishable customer claim.

usable

Incheon Grand Bridge application

The formula owner's project files record this application, and we publish it as what it is: a fact about where this formula has been used. No service life, condition report or performance story is derived from it — those come from your roof, measured.

blocked

Guaranteed temperatures or savings

Roof condition, climate, insulation, HVAC and use vary. No exact cooling or energy result is promised before a measured field record exists.

blocked

R-value, fireproof or total UV claims

These overstate what the available evidence establishes and are not part of the Sundown Coatings position.

Evidence discipline: Usable. Review. Blocked.. We publish the status, not only the headline.. 0.74 at three years, in writing.. No promised temperature. Ever.